05-4055A01, Rev. D GE MDS entraNET Reference Manual 21
Minimize the length of the power cabling, within reason.
When power is applied from a power source having a relatively
high (1 or 2 Ω) source impedance, or from a power source with-
out a large amount of output capacitance, no overshoot occurs.
Therefore, use a power supply that is rated appropriately for the
radio if possible—avoid using power supplies that far exceed
the radio's current requirements.
Please direct any questions you may have about interfacing to GE MDS
radios to GE MDS Technical Services at [email protected], or
telephone +1-585-241-5510.
STEP 3—CONFIGURE THE AP
The instructions below summarize essential AP settings for tabletop
testing. For detailed AP log-in and menu navigation instructions, see
ACCESSING THE MENU SYSTEM on Page 36.
Log-in and Configuration
The AP must be configured first, as Remote transceivers depend on the
AP beacon signal to achieve a connected (linked) state. Figure 2-5
shows the basic setup for configuring an AP with a personal computer.
Invisible place holder
Figure 2-5. AP Configuration Setup
Console Terminal
Connection
(recommended for
first-time log-in)
To configure the AP via a console terminal:
1. Connect a PC to the COM1 port on the radio.
2. Establish a terminal session (using HyperTerminal, for example)
using the following data parameters:
19200 bps
•8 bits
no parity
one stop bit (8N1)
hardware flow control disabled
VT100 emulation
PC Running Terminal Session
(19,200 bps, 8N1)
Access Point
COM1 or LAN P
o
(see text)
LAN
COM1
COM2
PWR
LINK