05-4055A01, Rev. D GE MDS entraNET Reference Manual 95
Figure 3-60. Redundancy Configuration Options Menu
Force Switchover—This selection invokes an immediate switcho-
ver from the active to the standby radio.
Invisible place holder
Network Interface Error—This selection is used to enable or dis-
able redundancy switchover on the occurrence of a Network
Interface Error. [Enabled, Disabled; Enabled]
Frequency Not Calibrated—This selection is used to enable or dis-
able redundancy switchover if a frequency calibration error
occurs. If this error occurs, the radio requires factory servicing.
[Enabled, Disabled; Enabled]
Power Not Calibrated—This selection is used to enable or disable
redundancy switchover if an RF power calibration error occurs.
If an error occurs, the radio requires factory servicing. [Enabled,
Disabled; Enabled
]
Lack of Associated Remotes Exceeded Threshold—This selection
brings up another screen (Figure 3-61) where you can specify
the duration of time that a redundant AP waits before consider-
ing itself to be malfunctioning. (A system must have at least one
associated Remote to be functional.)