104 GE MDS entraNET Reference Manual 05-4055A01, Rev. D
APx=<integer> —Configures a list of approved APs. x is a number from
1–50, and integer is the serial number of an approved AP (1–99999999).
To delete an entry, enter a serial number of 0; this indicates that the slot
is not filled.
AP1=<integer>Serial Number of approved AP
AP2=<integer>Serial Number of approved AP
.
.
.
AP50=<integer>Serial Number of approved AP
CLEAR—Clears all entries in the AP list. Be sure to set RESTRICT to OFF
before using this command to avoid restricting Remotes to associating
with an empty list.
CMD—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
RESTRICT=<ON|OFF>—Turns on or off restricting registration to APs in
the list.
ON—The Remote can only associate with an AP on the list.
OFF—The Remote can associate with any AP.
AUTH Displays the list of authorized features, or changes the Authorization
Key that controls these features.
Optional arguments:
KEY=<key>—Enter a valid authorization key (1–16 characters), which is
used to enable or disable software features.
(Example: AUTH KEY=123456abcdef)
CMD—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
COM1 Optional arguments:
BAUD=<bps>—Sets or displays the baud rate setting as 1200, 2400, 4800,
9600, 19200, 38400, 57600, or 115200 bps.
BUFFER=<bytes>—Sets or displays the maximum COM1 port buffer size
(1–1500).
CMD—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
DEFAULT=<mode>—Sets or displays the COM1 port default mode on
startup.
DEFAULT cannot be set to DATA unless the device has been autho-
rized for serial payload.